Home pagehome > Rashladna oprema > Blast Chileri: blast chileri

Blast Chileri: blast chileri

ICEMATIC T3

Tehnicke karakteristike:
Kapacitet: 3 x GN2/3
Dimenzija:600x600x400 mm
Snaga: 600W
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 7 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 5 kg

 

ICEMATIC T5/14 i T5/20

Tehnicke karakteristike:
Kapacitet: 5 x GN1/1 ili 5 x 600x400 mm
Dimenzija:800x700x900/930 mm
Snaga T5/14: 950 W

Snaga T5/20 1350 W

T5/14
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 14 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 8 kg

T5/20
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 20 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 12 kg

ICEMATIC T10/35

Tehnicke karakteristike:
Kapacitet: 10 x GN1/1 ili 10 x 600x400 mm
Dimenzija:800x700x1467/1522 mm
Snaga T10/35: 2850 W


T10/35
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 35 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 25 kg

ICEMATIC T15

Tehnicke karakteristike:
Kapacitet: 15 x GN1/1 ili 15 x 600x400 mm
Dimenzija:800x850x1950/2000 mm
Snaga T15/40: 2900 W

Snaga T15/65: 4000 W

T15/40
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 40 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 30 kg

T15/65
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 30 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 50 kg

ICEMATIC T15-2P

Tehnicke karakteristike:
Kapacitet: 30 x GN1/1 ili 30 x 600x400 mm
Dimenzija:800X1228X1950/2000 mm
Snaga T15-2P: 4350 W


T10/35
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 70 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 55 kg

ICEMATIC T20 compact

Tehnicke karakteristike:
Kapacitet: 1 KOLICA GN1/1 ili 1 KOLICA 600x400 mm
Dimenzija:890X1335X2410 mm
Snaga T20: 3900 W


T10/35
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 80 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 65 kg

ICEMATIC T20 - te

Tehnicke karakteristike:
Kapacitet: 20 x GN1/1 ili 20 x 600x400 mm
Dimenzija:900x1190x2270/2320 mm
Snaga T20-te/80: 3900 W

Snaga T20-te/110: 4700 W

T20-te/80
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 80 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 65 kg

T20-te/110
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 110 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 95 kg

ICEMATIC T20 - ca

Tehnicke karakteristike:
Kapacitet: 1 kolica GN1/1 ili 1 kolica 600x400 mm
Dimenzija:900x1190x2180 mm
Snaga T20-ca/80: 3900 W

Snaga T20-ca/110: 4700 W

T20-ca/80
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 80 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 65 kg

T20-ca/110
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 110 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 95 kg

ICEMATIC T20 - C +

Tehnicke karakteristike:
Kapacitet: 1 kolica GN1/1 ili 1 kolica 600x400 mm
Dimenzija:1040x1020x2250/2300 mm
Snaga T20-C+/80: 3900 W

Snaga T20-C+/110: 4700 W

T20-C+/80
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 80 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 65 kg

T20-C+/110
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 110 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 95 kg

ICEMATIC T24 - C +

Tehnicke karakteristike:
Kapacitet: 12 x GN2/1 ili 12 x 600x800 mm
Dimenzija:1250x1100x1505/1555 mm
Snaga T20-C+/80: 3900 W

Snaga T20-C+/110: 4700 W

T24/T24 C+/80
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 80 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 65 kg

T24/T24 C+/110
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 110 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 95 kg

ICEMATIC T30

Tehnicke karakteristike:
Kapacitet: 1 kolica GN2/1 ili 1 kolica 600x800 mm
Dimenzija:1370x1210x2274 mm

Snaga T30/110: 5000 W

Snaga T30/140: 5800 W

T30/110
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 110 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 95 kg

T30/140
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 140 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 125 kg

ICEMATIC T40

Tehnicke karakteristike:
Kapacitet: 1 kolica GN2/1 ili 1 kolica 800x1000 mm
Dimenzija:900x1900x2000 mm

Snaga T40/150: 5900 W

Snaga T40/200: 7850 W

T40/150
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 150 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 135 kg

T40/200
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 200 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 175 kg

ICEMATIC T50

Tehnicke karakteristike:
Kapacitet: 2 kolica GN2/1 ili 1 kolica 600x800 mm
Dimenzija:900x1450x2000 mm

Snaga T50/270: 11700 W

Snaga T50/400: 16350 W

T50/270
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 270 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 250 kg

T50/400
Chiller za 90 min spusta temperaturu
+ 90°C → +30°C = 390 kg
Freezer za 240 min spusta temperatu
+ 90°C → -18°C = 360 kg